{"id":3080,"date":"2020-11-26T12:21:50","date_gmt":"2020-11-26T12:21:50","guid":{"rendered":"https:\/\/www.sensortherm.de\/?page_id=3080"},"modified":"2026-06-29T08:07:37","modified_gmt":"2026-06-29T08:07:37","slug":"kalibrierstrahler-transfer-standard-pyrometer","status":"publish","type":"page","link":"https:\/\/www.sensortherm.de\/en\/calibration-sources-transfer-standard-pyrometers\/","title":{"rendered":"Calibration Sources \/ Transfer Standard Pyrometers"},"content":{"rendered":"<div class=\"et_pb_section_0 et_pb_section et_section_regular et_block_section\"><div class=\"et_pb_row_0 et_pb_row et_block_row\"><div class=\"et_pb_column_0 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_image_0 et_pb_image et_pb_module et_block_module\"><span class=\"et_pb_image_wrap\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2024\/04\/headerbild_kalibrierstahler_CS1500N.webp\" width=\"1080\" height=\"245\" srcset=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2024\/04\/headerbild_kalibrierstahler_CS1500N.webp 1080w, https:\/\/www.sensortherm.de\/wp-content\/uploads\/2024\/04\/headerbild_kalibrierstahler_CS1500N-980x222.webp 980w, https:\/\/www.sensortherm.de\/wp-content\/uploads\/2024\/04\/headerbild_kalibrierstahler_CS1500N-480x109.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1080px, 100vw\" class=\"wp-image-11958\" title=\"headerbild_kalibrierstahler_CS1500N\" alt=\"Headerbild Kalibrierstahler-Modell CS1500N\" \/><\/span><\/div><\/div><\/div><\/div><div class=\"et_pb_section_1 et_pb_section et_section_regular et_block_section\"><div class=\"et_pb_row_1 et_pb_row et_block_row\"><div class=\"et_pb_column_1 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_text_0 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module\"><div class=\"et_pb_text_inner\"><h1>Calibration Sources \/ Transfer Standard Pyrometers<\/h1>\n<\/div><\/div><\/div><\/div><div class=\"et_pb_row_2 et_pb_row et_block_row\"><div class=\"et_pb_column_2 et_pb_column et_pb_column_1_2 et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_text_1 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module\"><div class=\"et_pb_text_inner\"><p class=\"translation-block\"><strong>Calibration sources<\/strong>, also called blackbody calibration sources, provide stable temperatures to verify the functionality and accuracy of pyrometers, thermal imaging cameras and other devices for non-contact radiation measurement. <br>\nWith our <strong>calibration systems<\/strong>, calibration sources and pyrometers are automatically calibrated and adjusted.<\/p>\n<\/div><\/div><\/div><div class=\"et_pb_column_3 et_pb_column et_pb_column_1_2 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_text_2 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module\"><div class=\"et_pb_text_inner\"><p class=\"translation-block\"><strong>Transfer Standard Pyrometers<\/strong> are highly accurate and long-term stable pyrometers that are traced back to the international temperature scale ITS-90. With them, calibration sources are checked for their accuracy and readjusted if necessary, pyrometers are also checked for their accuracy using comparative measurements and also readjusted if necessary.<\/p>\n<\/div><\/div><\/div><\/div><\/div><div class=\"et_pb_section_2 et_pb_section et_section_regular et_block_section\"><div class=\"et_pb_row_3 et_pb_row et_pb_equal_columns et_block_row\"><div class=\"et_pb_column_4 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_image_1 et_pb_image et_pb_module et_block_module\"><span class=\"et_pb_image_wrap\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2025\/06\/kalibrierstrahlersystem_CS1500N_diadem-pyrometer.webp\" width=\"524\" height=\"321\" srcset=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2025\/06\/kalibrierstrahlersystem_CS1500N_diadem-pyrometer.webp 524w, https:\/\/www.sensortherm.de\/wp-content\/uploads\/2025\/06\/kalibrierstrahlersystem_CS1500N_diadem-pyrometer-480x294.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 524px, 100vw\" class=\"wp-image-12768\" title=\"kalibrierstrahlersystem_CS1500N_diadem-pyrometer\" alt=\"Kalibrierstrahler + Diadem-Transfer-Standard-Pyrometer + Laptop mit Justiersoftware\" \/><\/span><\/div><div class=\"et_pb_text_3 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module\"><div class=\"et_pb_text_inner\"><ul>\n<li>Fast heating-up times<\/li>\n<li>Very stable temperatures<\/li>\n<li>High emissivity of the cavity surface<\/li>\n<\/ul>\n<h2><a href=\"https:\/\/www.sensortherm.de\/en\/product\/cs1500-kalibrierstrahler\/\">CS1500N calibration source<\/a><\/h2>\n<ul>\n<li>Temperature range: 50 - 1500\u00b0C<\/li>\n<li>Aperture: 40 mm<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><strong><a href=\"https:\/\/www.sensortherm.de\/userfiles\/file\/datenblaetter\/en\/Sensortherm-Datasheet_CS1500N_SensorCal3-software.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2020\/08\/pdf-Icon.png\" width=\"25\" height=\"24\" alt=\"pdf-Icon\" class=\"wp-image-2092 alignnone size-full\" \/> Datasheet CS1500N + Software<\/a><\/strong><\/p>\n<\/div><\/div><\/div><\/div><div class=\"et_pb_row_4 et_pb_row et_pb_equal_columns et_block_row\"><div class=\"et_pb_column_5 et_pb_column et_pb_column_1_2 et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_text_4 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module\"><div class=\"et_pb_text_inner\"><h3><strong>The Calibration System<\/strong><\/h3>\n<ul>\n<li>Large temperature range of 50 to 1500\u00b0C<\/li>\n<li>Large aperture of 40 mm<\/li>\n<li>Sensortherm precision controller<\/li>\n<li>PC and pyrometer connection<\/li>\n<li>Software for automatic readjustment of the blackbody calibration source using a highly accurate DIADEM Transfer Standard Pyrometer<\/li>\n<li>Exact pyrometer check according to ITS-90, readjustment and certificate creation<\/li>\n<\/ul>\n<\/div><\/div><\/div><div class=\"et_pb_column_6 et_pb_column et_pb_column_1_2 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_code_0 et_pb_code et_pb_module\"><div class=\"et_pb_code_inner\"><iframe loading=\"lazy\" width=\"560\" height=\"315\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/rSYD_nRrCf0?si=sdBvn_kr8O9AYkVk\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen>?rel=0<\/iframe><\/div><\/div><\/div><\/div><div class=\"et_pb_row_5 et_pb_row et_block_row\"><div class=\"et_pb_column_7 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_image_2 et_pb_image et_pb_module et_block_module scale-image\"><a href=\"https:\/\/www.sensortherm.de\/en\/product\/diadem-di16-transfer-standard-pyrometer\/\"><span class=\"et_pb_image_wrap\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2024\/04\/CS1500N_Diadem-Pyrometer.webp\" width=\"524\" height=\"157\" srcset=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2024\/04\/CS1500N_Diadem-Pyrometer.webp 524w, https:\/\/www.sensortherm.de\/wp-content\/uploads\/2024\/04\/CS1500N_Diadem-Pyrometer-480x144.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 524px, 100vw\" class=\"wp-image-11960\" title=\"Diadem pyrometer aligned to the opening of the CS1500N calibration source\" alt=\"Diadem-Pyrometer ausgerichtet auf \u00d6ffnung vom Kalibrierstrahler CS1500N\" \/><\/span><\/a><\/div><div class=\"et_pb_text_5 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module\" id=\"diadem\"><div class=\"et_pb_text_inner\"><h2><a href=\"https:\/\/www.sensortherm.de\/en\/product\/diadem-di16-transfer-standard-pyrometer\/\">Transfer Standard Pyrometer DIADEM<\/a><\/h2>\n<ul>\n<li>Display resolution 0.01\u00b0<\/li>\n<li>Measurement uncertainty only 0.15% of the measured value + 1K<\/li>\n<\/ul>\n<p><a href=\"https:\/\/www.sensortherm.de\/userfiles\/file\/datenblaetter\/en\/Sensortherm-Datasheet_Diadem_DS06_DS09_DI13_DI16.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2020\/08\/pdf-Icon.png\" alt=\"pdf-Icon\" class=\"wp-image-2092 alignnone size-full\" width=\"25\" height=\"24\" \/> <strong>Datasheet DIADEM DS06 \/ DS09 \/ DI13 \/ DI16<\/strong><\/a><\/p>\n<\/div><\/div><\/div><\/div><div class=\"et_pb_row_6 et_pb_row et_block_row\"><div class=\"et_pb_column_8 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_text_6 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module\"><div class=\"et_pb_text_inner\"><p>DIADEM Transfer Standard Pyrometers are also used in-house, e.g. for our <a href=\"https:\/\/www.sensortherm.de\/en\/calibration-service\/\">calibration and adjustment service<\/a>.<\/p>\n<\/div><\/div><\/div><\/div><\/div><div class=\"et_pb_section_3 et_pb_section et_section_regular et_block_section\"><div class=\"et_pb_row_7 et_pb_row et_block_row\"><div class=\"et_pb_column_9 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_text_7 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module\" id=\"if\"><div class=\"et_pb_text_inner\"><h2>Software-Controlled Calibration and Adjustment with Calibration Systems<\/h2>\n<\/div><\/div><div class=\"et_pb_text_8 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module\"><div class=\"et_pb_text_inner\"><p>Our calibration sources can be used to verify infrared measuring devices from all manufacturers. However, the full potential is achieved in conjunction with Sensortherm devices:<\/p>\n<\/div><\/div><\/div><\/div><\/div><div class=\"et_pb_section_4 et_pb_section et_section_regular et_block_section\"><div class=\"et_pb_row_8 et_pb_row et_block_row\"><div class=\"et_pb_column_10 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_image_3 et_pb_image et_pb_module et_block_module scale-image\"><a href=\"https:\/\/www.sensortherm.de\/en\/pc-software\/#sensorcal3\"><span class=\"et_pb_image_wrap\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2024\/04\/Anschlussschema_N-Kalibriersysteme.webp\" width=\"524\" height=\"287\" srcset=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2024\/04\/Anschlussschema_N-Kalibriersysteme.webp 524w, https:\/\/www.sensortherm.de\/wp-content\/uploads\/2024\/04\/Anschlussschema_N-Kalibriersysteme-480x263.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 524px, 100vw\" class=\"wp-image-11961\" title=\"Anschlussschema_N-Kalibriersysteme\" alt=\"Anschlussschema Pyrometer mit Kalibrierstrahler und Steuersoftware\" \/><\/span><\/a><\/div><div class=\"et_pb_text_9 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module\"><div class=\"et_pb_text_inner\"><p>Pyrometer and PC can be connected to the calibration source and controlled via this. The result is a complete calibration and alignment system for both pyrometers and for the calibration source itself.<\/p>\n<\/div><\/div><div class=\"et_pb_text_10 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module\"><div class=\"et_pb_text_inner\"><h2 class=\"translation-block\"><a href=\"https:\/\/divi.sensortherm.de\/en\/pc-software#sensorcal3\" data-et-has-event-already=\"true\" target=\"_self\"><em>SensorCal3<\/em> Software <\/a><\/h2>\n<ul>\n<li>Kalibrierstrahler und METIS-Pyrometer nach langer Laufzeit einfach selber nachjustieren<\/li>\n<li>Create calibration certificates for calibration sources and METIS pyrometers<\/li>\n<\/ul>\n<\/div><\/div><\/div><\/div><div class=\"et_pb_row_9 et_pb_row et_block_row\"><div class=\"et_pb_column_11 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_text_11 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module\" id=\"if\"><div class=\"et_pb_text_inner\"><h2>Quick Check of Pyrometers<\/h2>\n<\/div><\/div><div class=\"et_pb_text_12 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module\"><div class=\"et_pb_text_inner\"><p>Der <a href=\"https:\/\/www.sensortherm.de\/en\/product\/he1200-temperature-source\/\"><strong>portable Temperaturstrahler HE1200N<\/strong><\/a> ist ein un\u00fcbertroffen schnell aufgeheizter sehr kleiner Temperaturstrahler. In nur 3 Minuten ist er auf bis zu 1200\u00b0C aufgeheizt und erlaubt es z.B. Pyrometer direkt an der Ofenanlage zu \u00fcberpr\u00fcfen oder erm\u00f6glicht es, bei Messungen durch Fenster oder Linsen die optischen Verluste zu ermitteln. Auch bei der <a href=\"https:\/\/www.sensortherm.de\/en\/highspeed-pyrometer\/#laserbearbeitungsoptikintegration\">Einkopplung des Pyrometers in eine Laser-Bearbeitungsoptik<\/a> ist das Pyrometer schnell an die dort anzutreffenden Verluste angepasst.<\/p>\n<\/div><\/div><\/div><\/div><div class=\"et_pb_row_10 et_pb_row et_block_row\"><div class=\"et_pb_column_12 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_image_4 et_pb_image et_pb_module et_block_module scale-image\"><a href=\"https:\/\/www.sensortherm.de\/en\/product\/he1200-temperature-source\/\"><span class=\"et_pb_image_wrap\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2024\/04\/HE1200N-Temperaturstrahler_Laserbearbeitungsoptik.webp\" width=\"504\" height=\"151\" srcset=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2024\/04\/HE1200N-Temperaturstrahler_Laserbearbeitungsoptik.webp 504w, https:\/\/www.sensortherm.de\/wp-content\/uploads\/2024\/04\/HE1200N-Temperaturstrahler_Laserbearbeitungsoptik-480x144.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 504px, 100vw\" class=\"wp-image-11962\" title=\"HE1200N-Temperaturstrahler_Laserbearbeitungsoptik\" alt=\"HE1200N und daneben Laserbearbeitungsoptik ausgerichtet auf Temperaturstrahler HE1200N\" \/><\/span><\/a><\/div><div class=\"et_pb_text_13 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module\" id=\"diadem\"><div class=\"et_pb_text_inner\"><h2>Temperatur\u00adstrahler HE1200N<\/h2>\n<ul>\n<li>Up to 1200\u00b0C in 3 minutes<\/li>\n<li>Optical losses determined quickly when taking measurements through windows or lenses<\/li>\n<\/ul>\n<p><a href=\"https:\/\/www.sensortherm.de\/userfiles\/file\/datenblaetter\/en\/Sensortherm-Datasheet_HE1200N_Temperature-Source.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2020\/08\/pdf-Icon.png\" alt=\"pdf-Icon\" class=\"wp-image-2092 alignnone size-full\" width=\"25\" height=\"24\" \/> <strong>Datasheet HE1200N<\/strong><\/a><\/p>\n<\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":50,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-3080","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.sensortherm.de\/en\/wp-json\/wp\/v2\/pages\/3080","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.sensortherm.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.sensortherm.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.sensortherm.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.sensortherm.de\/en\/wp-json\/wp\/v2\/comments?post=3080"}],"version-history":[{"count":8,"href":"https:\/\/www.sensortherm.de\/en\/wp-json\/wp\/v2\/pages\/3080\/revisions"}],"predecessor-version":[{"id":13688,"href":"https:\/\/www.sensortherm.de\/en\/wp-json\/wp\/v2\/pages\/3080\/revisions\/13688"}],"wp:attachment":[{"href":"https:\/\/www.sensortherm.de\/en\/wp-json\/wp\/v2\/media?parent=3080"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}