{"id":13789,"date":"2026-06-30T10:36:10","date_gmt":"2026-06-30T10:36:10","guid":{"rendered":"https:\/\/www.sensortherm.de\/?page_id=13789"},"modified":"2026-06-30T13:00:18","modified_gmt":"2026-06-30T13:00:18","slug":"highspeed-pyrometer","status":"publish","type":"page","link":"https:\/\/www.sensortherm.de\/de\/highspeed-pyrometer\/","title":{"rendered":"Highspeed-Pyrometer"},"content":{"rendered":"<div class=\"et_pb_section_0 et_pb_section et_section_regular et_flex_section\">\n<div class=\"et_pb_row_0 et_pb_row et_flex_row\">\n<div class=\"et_pb_column_0 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone\">\n<div class=\"et_pb_image_0 et_pb_image et_pb_module et_flex_module\"><span class=\"et_pb_image_wrap\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2021\/10\/headerbild_highspeedpyrometermessung.webp\" alt=\"Sehr schnell vorbeiziehende Metallteile mit Screenshot des Temperaturprofils\" title=\"headerbild_highspeedpyrometermessung\" width=\"1080\" height=\"257\" srcset=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2021\/10\/headerbild_highspeedpyrometermessung.webp 1080w, https:\/\/www.sensortherm.de\/wp-content\/uploads\/2021\/10\/headerbild_highspeedpyrometermessung-980x233.webp 980w, https:\/\/www.sensortherm.de\/wp-content\/uploads\/2021\/10\/headerbild_highspeedpyrometermessung-480x114.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1080px, 100vw\" class=\"wp-image-10076\" \/><\/span><\/div>\n<\/div>\n<\/div>\n\n<div class=\"et_pb_row_1 et_pb_row et_flex_row\">\n<div class=\"et_pb_column_1 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone\">\n<div class=\"et_pb_text_0 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><h1>Highspeedpyrometer<\/h1>\n<\/div><\/div>\n\n<div class=\"et_pb_text_1 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><p><strong>Highspeed-Pyrometer<\/strong> der <strong>Serien HELIOS H4 und METIS H3<\/strong> messen Temperaturen um ein vielfaches schneller als Standardger\u00e4te und erschlie\u00dfen damit spezielle Anwendungsbereiche wie z.B.:<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"et_pb_row_2 et_pb_row et_flex_row\">\n<div class=\"et_pb_column_2 et_pb_column et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_12_24 et_flex_column_12_24_tablet et_flex_column_24_24_phone\">\n<div class=\"et_pb_text_2 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><p>Thermische Prozesskontrolle mit gleichzeitiger Laser-Leistungssteuerung<\/p>\n<ul>\n<li>in der <strong>additiven Fertigung<\/strong>:\n<ul>\n<li><strong>Pulverbettschwei\u00dfen (SLM \/ SLS)<\/strong><\/li>\n<li><strong>Laserauftragschwei\u00dfen (LMD)<\/strong><\/li>\n<\/ul>\n<\/div><\/div>\n<\/div>\n\n<div class=\"et_pb_column_3 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_12_24 et_flex_column_12_24_tablet et_flex_column_24_24_phone\">\n<div class=\"et_pb_text_3 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><ul>\n<li>beim <strong>Laserl\u00f6ten<\/strong>\n<li>beim <strong>Laserh\u00e4rten<\/strong><\/li>\n<li>beim <strong>Laser-Kunststoffschwei\u00dfen<\/strong>.<\/li>\n<li>Zum Erstellen detaillierter <a href=\"https:\/\/www.sensortherm.de\/de\/anwendungen\/#profilmessung\"><strong>Temperaturprofile<\/strong><\/a> von schnell vorbeiziehenden Teilen.<\/li>\n<\/ul>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"et_pb_row_3 et_pb_row et_flex_row\">\n<div class=\"et_pb_column_4 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone\">\n<div class=\"et_pb_text_4 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><h2>Unsere Quotienten\u00adpyrometer zeichnen sich aus durch:<\/h2>\n<ul>\n<li><strong>H4:<\/strong> vollausgestattet mit Motorfokusobjektiv und PID-Regler zur direkten Stellgr\u00f6\u00dfenausgabe.<\/li>\n<li><strong>H3:<\/strong> im kompakten Geh\u00e4use mit integriertem Objektiv oder als Lichtleiter\u00adausf\u00fchrung. Optional mit integriertem PID-Regler zur direkten Stellgr\u00f6\u00dfenausgabe.<\/li>\n<li><strong>Digitale Ein- und Ausg\u00e4nge<\/strong> zur externen Ger\u00e4testeuerung sowie Ausgabe von Schaltsignalen bei Temperaturereignissen.<\/li>\n<li><strong>Einpunkt\u00adabgleichfunktion<\/strong> f\u00fcr die schnelle Anpassung an die Prozess\u00adtemperatur.<\/li>\n<li>Kommunikation \u00fcber <strong>Schnittstellen\u00adbefehle<\/strong> m\u00f6glich.<\/li>\n<\/ul>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"et_pb_row_4 et_pb_row et_flex_row\">\n<div class=\"et_pb_column_5 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone\">\n<div class=\"et_pb_text_5 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><div class=\"et_d4_element et_pb_column_4_4 et_pb_column et_pb_column_4  et_pb_css_mix_blend_mode_passthrough et-last-child et_block_column\">\n<div class=\"et_pb_module et_d4_element et_pb_text et_pb_text_4  et_pb_text_align_left et_pb_bg_layout_light\">\n<div class=\"et_pb_text_inner\">\n<h2>Highspeedpyrometer sind verf\u00fcgbar als:<\/h2>\n<\/div>\n<\/div>\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"et_pb_row_5 et_pb_row et_flex_row\">\n<div class=\"et_pb_column_6 et_pb_column et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_8_24 et_flex_column_8_24_tablet et_flex_column_24_24_phone\">\n<div class=\"et_pb_text_6 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><ul>\n<li><strong>Einfarbenpyrometer<\/strong> mit einer <strong>Erfassungs&shy;zeit von &lt; 20 \u00b5s<\/strong> f\u00fcr \u00fcber 50.000 Messungen \/ s (50\u00a0kHz Mess&shy;frequenz).<\/li>\n<li><strong>H3-<\/strong><a href=\"https:\/\/www.sensortherm.de\/de\/quotientenpyrometer\/\"><strong>Quotienten&shy;pyrometer<\/strong><\/a> mit einer <strong>Erfassungszeit von &lt; 40\u00a0\u00b5s<\/strong> f\u00fcr \u00fcber 25.000 Messungen \/ s (25\u00a0kHz Mess&shy;frequenz).<\/li>\n<li><strong>H4-<\/strong><a href=\"https:\/\/www.sensortherm.de\/de\/quotientenpyrometer\/\"><strong>Quotienten&shy;pyrometer<\/strong><\/a> mit einer <strong>Erfassungs&shy;zeit von &lt; 25 \u00b5s<\/strong> f\u00fcr \u00fcber 40.000 Messungen \/ s (40 kHz Mess&shy;frequenz).<\/li>\n<\/ul>\n<\/div><\/div>\n<\/div>\n\n<div class=\"et_pb_column_7 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_16_24 et_flex_column_16_24_tablet et_flex_column_24_24_phone\">\n<div class=\"et_pb_shop_0 et_pb_shop et_pb_shop_no_price et_pb_shop_no_rating et_pb_shop_no_sale_badge et_pb_module\" data-shortcode_index=\"0\"><div class=\"woocommerce columns-1 \"><ul class=\"products columns-1\">\n<li class=\"product type-product post-12616 status-publish first instock product_cat-highspeedpyrometer product_cat-quotientenpyrometer product_tag-helios product_tag-mitdownloads has-post-thumbnail shipping-taxable purchasable product-type-variable\">\n\t<a href=\"https:\/\/www.sensortherm.de\/de\/product\/helios-h422-highspeed-quotientenpyrometer\/\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><span class=\"et_shop_image\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2025\/05\/Helios_H4-Highspeed-Pyrometerserie-300x300.webp\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"Quotienten-Highspeedpyrometer mit PID-Regler f\u00fcr sehr schnelle ber\u00fchrungslose Temperaturmessung und Prozessregelung.\" \/><span class=\"et_overlay\"><\/span><\/span><h2 class=\"woocommerce-loop-product__title\">HELIOS H422 (Highspeed-Quotientenpyrometer)<\/h2>\n<\/a>\t\t<div itemprop=\"description\">\n\t\t\t<p style=\"text-align: left;\">Messbereich 700 \u2013 2300\u00b0C \/ 1292 \u2013 4172\u00b0F<br \/>\nSpektralbereich 1,45 \u2013 1,8 \u00b5m; &lt; 50 \u00b5s schnell<br \/>\nkleinstes Messfeld 0,8 mm<br \/>\nEthernet, Schalt-Ein- \/ Ausg\u00e4nge<\/p>\n\t\t<\/div>\n\t\t            \n            <\/li>\n<li class=\"product type-product post-12620 status-publish first instock product_cat-highspeedpyrometer product_cat-quotientenpyrometer product_tag-helios product_tag-mitdownloads has-post-thumbnail shipping-taxable purchasable product-type-variable\">\n\t<a href=\"https:\/\/www.sensortherm.de\/de\/product\/helios-h433-highspeed-quotientenpyrometer\/\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><span class=\"et_shop_image\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2025\/05\/Helios_H4-Highspeed-Pyrometerserie-300x300.webp\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"Quotienten-Highspeedpyrometer mit PID-Regler f\u00fcr sehr schnelle ber\u00fchrungslose Temperaturmessung und Prozessregelung.\" \/><span class=\"et_overlay\"><\/span><\/span><h2 class=\"woocommerce-loop-product__title\">HELIOS H433 (Highspeed-Quotientenpyrometer)<\/h2>\n<\/a>\t\t<div itemprop=\"description\">\n\t\t\t<p style=\"text-align: left;\">Messbereich 700 \u2013 2300\u00b0C \/ 1292 \u2013 4172\u00b0F<br \/>\nSpektralbereich 1,6 \u2013 2,1 \u00b5m; &lt; 50 \u00b5s schnell<br \/>\nkleinstes Messfeld 0,8 mm<br \/>\nEthernet, Schalt-Ein- \/ Ausg\u00e4nge<\/p>\n\t\t<\/div>\n\t\t            \n            <\/li>\n<li class=\"product type-product post-6671 status-publish first instock product_cat-highspeedpyrometer product_cat-quotientenpyrometer product_tag-metis product_tag-mitdownloads has-post-thumbnail shipping-taxable purchasable product-type-variable\">\n\t<a href=\"https:\/\/www.sensortherm.de\/de\/product\/metis-h322-highspeed-quotientenpyrometer\/\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><span class=\"et_shop_image\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2021\/04\/Metis_H3-Serie-300x300.webp\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"Einstellbare Highspeedpyrometer mit fokussierbarem Objektiv und Lichtleiterobjektiv\" \/><span class=\"et_overlay\"><\/span><\/span><h2 class=\"woocommerce-loop-product__title\">METIS H322 (Highspeed-Quotientenpyrometer)<\/h2>\n<\/a>\t\t<div itemprop=\"description\">\n\t\t\t<p style=\"text-align: left;\">8 Messbereiche zw. 350 und 3000\u00b0C \/ 662 und 5432\u00b0F<br \/>\nSpektralbereich 1,45 \u2013 1,8 \u00b5m; &lt; 80 \u00b5s schnell<br \/>\nkleinstes Messfeld 0,8 mm<br \/>\nDisplay, Einstelltasten, Schalt-Ein- \/ Ausg\u00e4nge<\/p>\n\t\t<\/div>\n\t\t            \n            <\/li>\n<li class=\"product type-product post-6669 status-publish first instock product_cat-highspeedpyrometer product_cat-quotientenpyrometer product_tag-metis product_tag-mitdownloads has-post-thumbnail shipping-taxable purchasable product-type-variable\">\n\t<a href=\"https:\/\/www.sensortherm.de\/de\/product\/metis-h311-highspeed-quotientenpyrometer\/\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><span class=\"et_shop_image\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2021\/04\/Metis_H3-Serie-300x300.webp\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"Einstellbare Highspeedpyrometer mit fokussierbarem Objektiv und Lichtleiterobjektiv\" \/><span class=\"et_overlay\"><\/span><\/span><h2 class=\"woocommerce-loop-product__title\">METIS H311 (Highspeed-Quotientenpyrometer)<\/h2>\n<\/a>\t\t<div itemprop=\"description\">\n\t\t\t<p style=\"text-align: left;\">7 Messbereiche zw. 600 und 3300\u00b0C \/ 1112 und 5972\u00b0F<br \/>\nSpektralbereich 0,75 \u2013 1,1 \u00b5m; &lt; 80 \u00b5s schnell<br \/>\nkleinstes Messfeld 0,8 mm<br \/>\nDisplay, Einstelltasten, Schalt-Ein- \/ Ausg\u00e4nge<\/p>\n\t\t<\/div>\n\t\t            \n            <\/li>\n<li class=\"product type-product post-6667 status-publish first instock product_cat-einfarbenpyrometer product_cat-highspeedpyrometer product_tag-metis product_tag-mitdownloads has-post-thumbnail shipping-taxable purchasable product-type-variable\">\n\t<a href=\"https:\/\/www.sensortherm.de\/de\/product\/metis-h318-highspeed-einfarbenpyrometer\/\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><span class=\"et_shop_image\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2021\/04\/Metis_H3-Serie-300x300.webp\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"Einstellbare Highspeedpyrometer mit fokussierbarem Objektiv und Lichtleiterobjektiv\" \/><span class=\"et_overlay\"><\/span><\/span><h2 class=\"woocommerce-loop-product__title\">METIS H318 (Highspeed-Einfarbenpyrometer)<\/h2>\n<\/a>\t\t<div itemprop=\"description\">\n\t\t\t<p style=\"text-align: left;\">2 Messbereiche zw. 120 und 800\u00b0C \/ 248 und 1472\u00b0F<br \/>\nSpektralbereich 1,65 \u2013 2,1 \u00b5m; &lt; 40 \u00b5s schnell<br \/>\nkleinstes Messfeld 0,4 mm<br \/>\nDisplay, Einstelltasten, Schalt-Ein- \/ Ausg\u00e4nge<\/p>\n\t\t<\/div>\n\t\t            \n            <\/li>\n<li class=\"product type-product post-6665 status-publish first instock product_cat-einfarbenpyrometer product_cat-highspeedpyrometer product_tag-metis product_tag-mitdownloads has-post-thumbnail shipping-taxable purchasable product-type-variable\">\n\t<a href=\"https:\/\/www.sensortherm.de\/de\/product\/metis-h316-highspeed-einfarbenpyrometer\/\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><span class=\"et_shop_image\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2021\/04\/Metis_H3-Serie-300x300.webp\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"Einstellbare Highspeedpyrometer mit fokussierbarem Objektiv und Lichtleiterobjektiv\" \/><span class=\"et_overlay\"><\/span><\/span><h2 class=\"woocommerce-loop-product__title\">METIS H316 (Highspeed-Einfarbenpyrometer)<\/h2>\n<\/a>\t\t<div itemprop=\"description\">\n\t\t\t<p style=\"text-align: left;\">7 Messbereiche zw. 250 und 2500\u00b0C \/ 482 und 4532\u00b0F<br \/>\nSpektralbereich 1,45 \u2013 1,8 \u00b5m; &lt; 40 \u00b5s schnell<br \/>\nkleinstes Messfeld 0,4 mm<br \/>\nDisplay, Einstelltasten, Schalt-Ein- \/ Ausg\u00e4nge<\/p>\n\t\t<\/div>\n\t\t            \n            <\/li>\n<li class=\"product type-product post-6029 status-publish first instock product_cat-einfarbenpyrometer product_cat-highspeedpyrometer product_tag-metis product_tag-mitdownloads has-post-thumbnail shipping-taxable purchasable product-type-variable\">\n\t<a href=\"https:\/\/www.sensortherm.de\/de\/product\/metis-h309-highspeed-einfarbenpyrometer\/\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><span class=\"et_shop_image\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2021\/04\/Metis_H3-Serie-300x300.webp\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"Einstellbare Highspeedpyrometer mit fokussierbarem Objektiv und Lichtleiterobjektiv\" \/><span class=\"et_overlay\"><\/span><\/span><h2 class=\"woocommerce-loop-product__title\">METIS H309 (Highspeed-Einfarbenpyrometer)<\/h2>\n<\/a>\t\t<div itemprop=\"description\">\n\t\t\t<p style=\"text-align: left;\">5 Messbereiche zw. 550 und 2000\u00b0C \/ 1022 und 3632\u00b0F<br \/>\nSpektralbereich 0,7 &#8211; 1,1 \u00b5m; &lt; 40 \u00b5s schnell<br \/>\nkleinstes Messfeld 0,4 mm<br \/>\nDisplay, Einstelltasten, Schalt-Ein- \/ Ausg\u00e4nge<\/p>\n\t\t<\/div>\n\t\t            \n            <\/li>\n<li class=\"product type-product post-5624 status-publish first instock product_cat-einfarbenpyrometer product_cat-highspeedpyrometer product_cat-quotientenpyrometer product_tag-metis product_tag-mitdownloads has-post-thumbnail shipping-taxable purchasable product-type-variable\">\n\t<a href=\"https:\/\/www.sensortherm.de\/de\/product\/heavy-duty-messsystem\/\" class=\"woocommerce-LoopProduct-link woocommerce-loop-product__link\"><span class=\"et_shop_image\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2021\/03\/Heavy-Duty-Messsystem-300x300.webp\" class=\"attachment-woocommerce_thumbnail size-woocommerce_thumbnail\" alt=\"Heavy-Duty-Pyrometer-Messsystem f\u00fcr den Einsatz in rauen Umgebungs\u00adbedingun\u00adgen\" \/><span class=\"et_overlay\"><\/span><\/span><h2 class=\"woocommerce-loop-product__title\">Heavy-Duty-Messsystem f\u00fcr METIS-M3- oder H3-Pyrometer<\/h2>\n<\/a>\t\t<div itemprop=\"description\">\n\t\t\t<p>Fokusabstand bis zu 4,5 m<br \/>\nEinsatz bis zu 250\u00b0C am Messkopf<br \/>\nEdelstahl-Gewebeschlauch in L\u00e4ngen bis zu 30 m<br \/>\nFreiblasvorrichtung f\u00fcr das Objektivsystem<\/p>\n\t\t<\/div>\n\t\t            \n            <\/li>\n<\/ul>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"et_pb_row_6 et_pb_row et_flex_row\">\n<div class=\"et_pb_column_8 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone\">\n<div class=\"et_pb_text_7 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><h2>Typische Anwendung: Integration in Lasersysteme bzw. in Laser-Bearbeitungsoptiken<\/h2>\n<div class=\"et_d4_element et_pb_column_4_4 et_pb_column et_pb_column_9  et_pb_css_mix_blend_mode_passthrough et-last-child et_block_column\">\n<div class=\"et_pb_module et_d4_element et_pb_text et_pb_text_9  et_pb_text_align_left et_pb_bg_layout_light\">\n<div class=\"et_pb_text_inner\">\n<p>Bei Laserprozessen wie der additiven Fertigung, dem Laserl\u00f6ten, Laserh\u00e4rten oder Laser-Kunststoffschwei\u00dfen kann ein in die Laseroptik integriertes Pyrometer die Temperatur der Schmelze an der Bauteiloberfl\u00e4che \u00fcberwachen. Damit werden dem Laserroboter in Echtzeit Temperaturdaten geliefert, mit der die Laserleistung so geregelt wird, dass immer die ben\u00f6tigte Solltemperatur am Bauteil eingehalten wird.<\/p>\n<p><strong>Beispiel additive Fertigung<\/strong><\/p>\n<p>Bei der additiven Fertigung ist die Temperatur\u00fcberwachung und -regelung mit Pyrometern die wichtigste Voraussetzung f\u00fcr eine gleichm\u00e4\u00dfige Materialbeschichtung.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"et_pb_row_7 et_pb_row et_flex_row\">\n<div class=\"et_pb_column_9 et_pb_column et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_12_24 et_flex_column_12_24_tablet et_flex_column_24_24_phone\">\n<div class=\"et_pb_image_1 et_pb_image et_pb_module et_flex_module\"><span class=\"et_pb_image_wrap\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2021\/11\/Schaufel_additiv_ungeregelt.webp\" alt=\"Erste Schichten einer additiv gefertigten Schaufel zeigen eine ungleichm\u00e4\u00dfige Materialbeschichtung\" title=\"Schaufel_additiv_ungeregelt\" width=\"524\" height=\"177\" srcset=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2021\/11\/Schaufel_additiv_ungeregelt.webp 524w, https:\/\/www.sensortherm.de\/wp-content\/uploads\/2021\/11\/Schaufel_additiv_ungeregelt-480x162.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 524px, 100vw\" class=\"wp-image-10475\" \/><\/span><\/div>\n\n<div class=\"et_pb_text_8 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><p>Mit <strong>konstanter Laser\u00adleistung ergeben sich unkonstante Oberfl\u00e4chen\u00ad\u00adtemperaturen<\/strong>, die eine ungleichm\u00e4\u00dfige Material\u00adbeschichtung verursachen k\u00f6nnen.<\/p>\n<\/div><\/div>\n<\/div>\n\n<div class=\"et_pb_column_10 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_12_24 et_flex_column_12_24_tablet et_flex_column_24_24_phone\">\n<div class=\"et_pb_image_2 et_pb_image et_pb_module et_flex_module\"><span class=\"et_pb_image_wrap\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2021\/11\/Schaufel_additiv_geregelt.webp\" alt=\"Erste Schichten einer additiv gefertigten und geregelten Schaufel zeigen eine gleichm\u00e4\u00dfige Materialbeschichtung\" title=\"Schaufel_additiv_geregelt\" width=\"524\" height=\"177\" srcset=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2021\/11\/Schaufel_additiv_geregelt.webp 524w, https:\/\/www.sensortherm.de\/wp-content\/uploads\/2021\/11\/Schaufel_additiv_geregelt-480x162.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 524px, 100vw\" class=\"wp-image-10476\" \/><\/span><\/div>\n\n<div class=\"et_pb_text_9 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><p>Wird die <strong>Oberfl\u00e4chen\u00adtemperatur kontinu\u00adierlich \u00fcberwacht<\/strong>, kann die Laser\u00adausgangs\u00adleistung genauso kontinuierlich mitgeregelt werden und erf\u00fcllt damit eine wichtige Voraussetzung f\u00fcr gleichm\u00e4\u00dfige Materialbeschichtungen.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"et_pb_row_8 et_pb_row et_flex_row\">\n<div class=\"et_pb_column_11 et_pb_column et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_12_24 et_flex_column_12_24_tablet et_flex_column_24_24_phone\">\n<div class=\"et_pb_image_3 et_pb_image et_pb_module et_flex_module\"><span class=\"et_pb_image_wrap\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2021\/11\/Screenshot_Laserleistung_konstant.webp\" alt=\"Software-Screenshot (Graph), der eine ungleichm\u00e4\u00dfige Materialtemperatur zeigt, wenn eine konstante Laserausgangsleistung verwendet wird\" title=\"Screenshot_Laserleistung_konstant\" width=\"524\" height=\"380\" srcset=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2021\/11\/Screenshot_Laserleistung_konstant.webp 524w, https:\/\/www.sensortherm.de\/wp-content\/uploads\/2021\/11\/Screenshot_Laserleistung_konstant-480x348.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 524px, 100vw\" class=\"wp-image-10478\" \/><\/span><\/div>\n<\/div>\n\n<div class=\"et_pb_column_12 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_12_24 et_flex_column_12_24_tablet et_flex_column_24_24_phone\">\n<div class=\"et_pb_image_4 et_pb_image et_pb_module et_flex_module\"><span class=\"et_pb_image_wrap\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2021\/11\/Screenshot_Laserleistung_geregelt.webp\" alt=\"Software-Screenshot (Graph), der eine gleichm\u00e4\u00dfige Materialtemperatur zeigt, wenn eine geregelte Laserausgangsleistung eingesetzt wird\" title=\"Screenshot_Laserleistung_geregelt\" width=\"524\" height=\"380\" srcset=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2021\/11\/Screenshot_Laserleistung_geregelt.webp 524w, https:\/\/www.sensortherm.de\/wp-content\/uploads\/2021\/11\/Screenshot_Laserleistung_geregelt-480x348.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 524px, 100vw\" class=\"wp-image-10477\" \/><\/span><\/div>\n<\/div>\n<\/div>\n\n<div class=\"et_pb_row_9 et_pb_row et_flex_row\">\n<div class=\"et_pb_column_13 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone\">\n<div class=\"et_pb_text_10 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><h2>Typische Anwendung: Laserh\u00e4rten<\/h2>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"et_pb_row_10 et_pb_row et_flex_row\">\n<div class=\"et_pb_column_14 et_pb_column et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_3_5 et_flex_column_3_5_tablet et_flex_column_24_24_phone\">\n<div class=\"et_pb_text_11 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><p><strong>Temperatur&shy;geregeltes Laser&shy;h\u00e4rten<\/strong> erzeugt perfekte H\u00e4rte&shy;ergebnisse durch geeignete Temperatur&shy;regelung. Auch bei ange&shy;haltenem Laser, unter&shy;schiedlichen Geschwindig&shy;keiten oder Zunder. Nach Entfernen der Oxidschicht sind keine An&shy;schmelzungen zu erkennen.<\/p>\n<\/div><\/div>\n\n<div class=\"et_pb_video_0 et_pb_video et_pb_module et_flex_module\"><div class=\"et_pb_video_box\"><video controls><source type=\"video\/mp4\" src=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2021\/02\/Video_Temperaturgeregeltes_Laser-Haerten_web.mp4\" \/><\/video><\/div><div class=\"et_pb_video_overlay\" style=\"background-image:url(https:\/\/www.sensortherm.de\/wp-content\/uploads\/2021\/06\/Vorschaubild_Video_Laserhaerten.webp)\"><div class=\"et_pb_video_overlay_hover\"><a class=\"et_pb_video_play\" href=\"#\"><\/a><\/div><\/div><\/div>\n<\/div>\n\n<div class=\"et_pb_column_15 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_2_5 et_flex_column_2_5_tablet et_flex_column_24_24_phone\">\n<div class=\"et_pb_text_12 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><p><strong>Temperatur\u00adgeregeltes Laser\u00adh\u00e4rten<\/strong> erm\u00f6glicht selbst bei unterschiedlichen Oberfl\u00e4chen\u00adbedingungen wie Gewinde\u00adbohrungen mit d\u00fcnnen oder scharfen Kanten gleichbleibende Ergebnisse ohne Abbrand.<\/p>\n<\/div><\/div>\n\n<div class=\"et_pb_video_1 et_pb_video et_pb_module et_flex_module\"><div class=\"et_pb_video_box\"><iframe loading=\"lazy\" title=\"Laserspurh\u00e4rten mit dem Highspeed-Pyrometer METIS H3\" width=\"1080\" height=\"810\" src=\"https:\/\/www.youtube.com\/embed\/G8GbTYqJdpw?feature=oembed\"  allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div><div class=\"et_pb_video_overlay\" style=\"background-image:url(\/\/i.ytimg.com\/vi\/G8GbTYqJdpw\/hqdefault.jpg)\"><div class=\"et_pb_video_overlay_hover\"><a class=\"et_pb_video_play\" href=\"#\"><\/a><\/div><\/div><\/div>\n\n<div class=\"et_pb_text_13 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><p>Hinweis: Mit dem Klick auf das Video wird eine Verbindung zu YouTube hergestellt. Dabei werden Daten an Google \u00fcbertragen.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"et_pb_row_11 et_pb_row et_flex_row\">\n<div class=\"et_pb_column_16 et_pb_column et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_12_24 et_flex_column_12_24_tablet et_flex_column_24_24_phone\">\n<div class=\"et_pb_text_14 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><h2>Messmethoden \/ Pyrometer-Einkopplung<\/h2>\n<p>Das Pyrometer kann neben dem Bearbeitungs\u00adlaser montiert auf die erhitzte Messstelle ausgerichtet werden oder in den Laserkopf mit einge\u00adkoppelt werden, die Messung erfolgt dann immer an der gleichen Stelle, an der sich der Laser befindet.<\/p>\n<\/div><\/div>\n<\/div>\n\n<div class=\"et_pb_column_17 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_12_24 et_flex_column_12_24_tablet et_flex_column_24_24_phone\">\n<div class=\"et_pb_video_2 et_pb_video et_pb_module et_flex_module\"><div class=\"et_pb_video_box\"><iframe loading=\"lazy\" title=\"H4 Highspeed-Laser-Regelpyrometer\" width=\"1080\" height=\"608\" src=\"https:\/\/www.youtube.com\/embed\/9y9cboVn1yI?feature=oembed\"  allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div><div class=\"et_pb_video_overlay\" style=\"background-image:url(\/\/i.ytimg.com\/vi\/9y9cboVn1yI\/maxresdefault.jpg)\"><div class=\"et_pb_video_overlay_hover\"><a class=\"et_pb_video_play\" href=\"#\"><\/a><\/div><\/div><\/div>\n\n<div class=\"et_pb_text_15 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><p>Hinweis: Mit dem Klick auf das Video wird eine Verbindung zu YouTube hergestellt. Dabei werden Daten an Google \u00fcbertragen.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"et_pb_row_12 et_pb_row et_flex_row\">\n<div class=\"et_pb_column_18 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone\">\n<div class=\"et_pb_text_16 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><h3>Eingekoppelte Systeme bieten die Vorteile:<\/h3>\n<ul>\n<li>Abgeschlossenes System ohne Objektiv\u00adverschmutzung.<\/li>\n<li>On-Axis-\u00adEin\u00adkopp\u00adlungen sind auch in Laserk\u00f6pfe mit Spiegel- und Rotations\u00adscannern m\u00f6glich.<\/li>\n<li>Die Messung von komplexen Werkst\u00fcck\u00adgeometrien mit Anpassung der Laser\u00adleistung nahezu in Echtzeit bietet eine professionelle Alternative zur konventionellen thermischen Prozess\u00adkontrolle mit Thermovisions\u00adkameras, die lediglich die nachtr\u00e4gliche Qualit\u00e4ts\u00ad\u00fcberpr\u00fcfung erm\u00f6glichen, aber nicht aktiv in den Laser-Regel-Prozess eingreifen.<\/li>\n<\/ul>\n<\/div><\/div>\n\n<div class=\"et_pb_text_17 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><p><a href=\"https:\/\/www.sensortherm.de\/userfiles\/file\/datenblaetter\/application\/Sensortherm-Anwendung_Laserleistungsreglung.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.sensortherm.de\/wp-content\/uploads\/2020\/08\/pdf-Icon.png\" alt=\"pdf-Icon\" class=\"wp-image-2092 alignnone size-full\" width=\"25\" height=\"24\" \/><\/a> Unsere pdf-Brosch\u00fcre \u201e<a rel=\"noopener noreferrer\" aria-label=\"Highspeed-Pyrometer zur Laserleistungsreglung (\u00f6ffnet in neuem Tab)\" href=\"https:\/\/www.sensortherm.de\/userfiles\/file\/datenblaetter\/application\/Sensortherm-Anwendung_Laserleistungsreglung.pdf\" target=\"_blank\">Highspeed-Pyrometer zur Laserleistungsreglung<\/a>\u201c gibt einen \u00dcberblick \u00fcber das System, Ger\u00e4te und die M\u00f6glichkeiten.<\/p>\n<\/div><\/div>\n\n<div class=\"et_pb_text_18 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><p>Wir empfehlen immer eine <a href=\"https:\/\/www.sensortherm.de\/de\/kontakt\/\">pers\u00f6nliche Vorab-Beratung<\/a>, bevor Sie sich f\u00fcr ein Ger\u00e4t entscheiden.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-13789","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.sensortherm.de\/de\/wp-json\/wp\/v2\/pages\/13789","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.sensortherm.de\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.sensortherm.de\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.sensortherm.de\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.sensortherm.de\/de\/wp-json\/wp\/v2\/comments?post=13789"}],"version-history":[{"count":8,"href":"https:\/\/www.sensortherm.de\/de\/wp-json\/wp\/v2\/pages\/13789\/revisions"}],"predecessor-version":[{"id":13819,"href":"https:\/\/www.sensortherm.de\/de\/wp-json\/wp\/v2\/pages\/13789\/revisions\/13819"}],"wp:attachment":[{"href":"https:\/\/www.sensortherm.de\/de\/wp-json\/wp\/v2\/media?parent=13789"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}